FANUC Alarm SPOT-082 — PAUSE Bad schedule (S=…)-gun 1

Manufacturer wording — PAUSE Bad schedule (S=%s)-gun 1
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC SPOT-082 (“PAUSE Bad schedule (S=…)-gun 1”): An inavlid weld schedule was programmed in the teach pendant program. First check: Check the S= value of the current line of the teach pendant program.

Updated 2026-09-17 · LogrobotLM reference

Description

An inavlid weld schedule was programmed in the teach pendant program.

Remedy

Check the S= value of the current line of the teach pendant program. The smallest schedule number allowed is 0. For digital weld controllers, the largest schedule number allowed depends on the width of the Weld Schedule group output. If this GOUT is 4 I/O points wide, then the maximum schedule is 15. If the GOUT is 5 I/O points wide, then the maximum scheudule is 31. For serial weld controllers, the maximum schedule is 32. Re-program the S= value in the teach pendant program.

Related codes