LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SPOT-087 — PAUSE GUN OPEN timed out-gun 1

FANUC SPOT-087 (“PAUSE GUN OPEN timed out-gun 1”): The robot timed out waiting for the gun to open. First check: Check the Equipment I/O menu, as well as all wiring.

Updated 2026-09-17 · LogrobotLM reference

Description

The robot timed out waiting for the gun to open.

Remedy

Check the Equipment I/O menu, as well as all wiring. If the input is going high, try increasing the timeout by setting $spoteqsetup[].$bu_cl_to (gun open = backup close) to a bigger number. The default is 2000 ms, or 2 seconds.

Related codes