FANUC Alarm SRVO-047 — SERVO LVAL alarm

Error
Hardware
servo amplifier
Controllers
R-J3iB / R-30iA / R-30iB
FANUC class
SERVO

Manufacturer wording — SERVO LVAL alarm(Group:%d Axis:%d)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC SRVO-047 (“SERVO LVAL alarm”): Despite the external magnetic contactor for a servo amplifier being on, the DC voltage (DC link voltage) of the main circuit power supply or the control power supply voltage (+5 V) is excessively low. First check: When the LED indicator on the servo amplifier displays '6' (this alarm is issued when the control power supply voltage (+5 V) is excessively low): 1. Likely part: Servo amplifier (Servo amplifier).

Updated 2026-10-22 · LogrobotLM reference

Description

Despite the external magnetic contactor for a servo amplifier being on, the DC voltage (DC link voltage) of the main circuit power supply or the control power supply voltage (+5 V) is excessively low.

Remedy

When the LED indicator on the servo amplifier displays '6' (this alarm is issued when the control power supply voltage (+5 V) is excessively low): 1. Replace the servo amplifier. 2. Replace the power supply PCB.

Field diagnosis

The internal control voltage of the amplifier (5 V and associated voltages) is too low.

What to check

  • Check the upstream power supply; replace the amplifier, then the power supply unit if the code persists.
  • Note: On R-30iA Mate, the PSM variant is SRVO-131.

Part to check / replace

FANUC SRVO-047 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.