FANUC Alarm SRVO-045 — SERVO HCAL alarm

Error
Hardware
servo amplifier
Controllers
R-J3iB / R-30iA / R-30iB
FANUC class
SERVO

Manufacturer wording — SERVO HCAL alarm(Group:%d Axis:%d)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC SRVO-045 (“SERVO HCAL alarm”): An excessively high current flowed through the main circuit of a servo amplifier. First check: 1. Relax operating conditions if cooling down clears this problem.

Updated 2026-10-22 · LogrobotLM reference

Description

An excessively high current flowed through the main circuit of a servo amplifier. The LED indicator on the servo amplifier PSM displays '-'. One of the red LEDs (HC1 to HC6) above the 7segment LED is lit, indicating the axis for which the HCAL alarm is detected.

Remedy

1. Relax operating conditions if cooling down clears this problem. 2. Disconnect the

Field diagnosis

Abnormally high current in the amplifier main circuit: motor or cable short circuit, or failed power transistor.

What to check

  • With the power off, disconnect the power cable of the reported axis and the brake cable (to prevent the axis from falling); switch the power back on.
  • Code present without the motor: amplifier.
  • Code absent: measure the insulation between U, V, W and ground on the robot connection cable and the internal cable, then on the motor; replace the faulty item.
  • Note: Never reconnect a suspect motor to a new amplifier without measuring it first: you will burn out the second one.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →