LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SRVO-073 — SERVO CMAL alarm

Error
Hardware
Pulsecoder (encoder)
Controllers
R-J3iB / R-30iA / R-30iB
FANUC class
SERVO2

Manufacturer wording — SERVO CMAL alarm(Group:%d Axis:%d)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC SRVO-073 (“SERVO CMAL alarm”): The pulse coder might be faulty, or noise might be causing the pulse coder to malfunction. First check: Perform simple mastering and improve the shielding.

Updated 2026-10-22 · LogrobotLM reference

Description

The pulse coder might be faulty, or noise might be causing the pulse coder to malfunction.

Remedy

Perform simple mastering and improve the shielding.

Field diagnosis

The Pulsecoder is faulty or disturbed by electrical noise.

What to check

  • Check the cabinet grounding and the connection of the shields to the ground plate; improve the grounding of the motor flange (especially on auxiliary axes).
  • Then replace the Pulsecoder and redo the mastering.
  • On some versions the code requires a power cycle.
  • Note: CMAL followed by SRVO-075: the position is no longer established; jogging by one motor revolution re-establishes it.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →