FANUC Alarm SRVO-242SERVO Chain 1 (EXEMG) abnormal

FANUC SRVO-242 (“SERVO Chain 1 (EXEMG) abnormal”): A single chain 1 (+24V) failure occurred when External Emergency stop input was asserted. First check: 1. Repair the circuit of the chain 1 (+24V) on the External Emergency stop hardware.

Updated 2026-08-29 · LogrobotLM reference

Description

A single chain 1 (+24V) failure occurred when External Emergency stop input was asserted.

Remedy · Remède

1. Repair the circuit of the chain 1 (+24V) on the External Emergency stop hardware. 2. Set CHAIN FAILURE detection to TRUE on SYSTEM/CONFIG the screen. 3. Press RESET on the teach pendant.

Frequently asked · Questions fréquentes

What does FANUC alarm SRVO-242 mean?
FANUC SRVO-242 (“SERVO Chain 1 (EXEMG) abnormal”): A single chain 1 (+24V) failure occurred when External Emergency stop input was asserted.
How do you troubleshoot FANUC alarm SRVO-242?
1. Repair the circuit of the chain 1 (+24V) on the External Emergency stop hardware. 2. Set CHAIN FAILURE detection to TRUE on SYSTEM/CONFIG the screen. 3. Press RESET on the teach pendant.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →