FANUC Alarm SRVO-251 — DB relay abnormal

Error
Hardware
servo amplifier
Controllers
R-30iA / R-30iB
FANUC class
SERVO

Manufacturer wording — DB relay abnormal(G:%d A:%d)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC SRVO-251 (“DB relay abnormal”): The dynamic brake relay in the amplifier is abnormal. First check: Replace the amplifier. Likely part: Servo amplifier (Servo amplifier).

Updated 2026-10-22 · LogrobotLM reference

Description

The dynamic brake relay in the amplifier is abnormal.

Remedy

Replace the amplifier.

Field diagnosis

The internal dynamic brake relay of the amplifier is faulty.

What to check

  • Replace the amplifier; on R-30iB, the emergency stop unit second.
  • Note: No on-site repair possible.

Part to check / replace

FANUC SRVO-251 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Same hardware involved