FANUC Alarm SRVO-250 — SERVO SVEMG/MAINON1 abnormal

Error
Hardware
emergency stop and dual safety chains
Controllers
R-J3iB / R-30iA
FANUC class
SERVO

FANUC SRVO-250 (“SERVO SVEMG/MAINON1 abnormal”): Status of MAINON1 signal is still OFF even if SVEMG is ON It is abnormal of E.STOP First check: Repair the circuit of E.Stop hardware Power off/on again

Updated 2026-10-22 · LogrobotLM reference

Description

Status of MAINON1 signal is still OFF even if SVEMG is ON It is abnormal of E.STOP

Remedy

Repair the circuit of E.Stop hardware Power off/on again

Field diagnosis

The SVEMG signal is active but MAINON1 stays inactive: the emergency stop circuit does not report the expected state.

What to check

  • Repair the emergency stop circuit (E-stop unit connectors, relays), then switch the mains power off and back on to clear.
  • Note: Code from the R-J3iB/R-30iA generation; on R-30iB, the same family of fault appears as SRVO-348/349.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →