FANUC Alarm SRVO-271 — SERVO EXEMG2 status abnormal
Error- Hardware
- emergency stop and dual safety chains
- Controllers
- R-J3iB / R-30iA / R-30iB
- FANUC class
- SERVO
- Hardware family
- FANUC emergency stop, pendant and dual safety chain alarms
FANUC SRVO-271 (“SERVO EXEMG2 status abnormal”): The SVDISC1 status is still ON when the SVDISC signal is asserted. First check: Repair the SVDISC1 circuit.
Updated 2026-10-22 · LogrobotLM reference
Description
The SVDISC1 status is still ON when the SVDISC signal is asserted.
Remedy
Repair the SVDISC1 circuit.
Field diagnosis
Chain alarm on channel 2 of the external emergency stop.
What to check
- EES circuit on both channels, timing, then the teach pendant cable and the emergency stop board.
- Release: emergency stop pressed/released, RES_1CH, RESET.
- Note: Read together with SRVO-270: lagging channel or board.
Related codes