LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SRVO-292 — SERVO EXT.FAN alarm

Error
Hardware
cabinet cooling
Controllers
R-J3iB / R-30iA
FANUC class
SERVO

Manufacturer wording — SERVO EXT.FAN alarm (G:%d A:%d)
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC SRVO-292 (“SERVO EXT.FAN alarm”): DC link high current alarm occured on the PSM Input power is abnormal or PSM unit is broken First check: Check input power to PSM Check the voltage between U-V,V-W,and U-W.

Updated 2026-10-22 · LogrobotLM reference

Description

DC link high current alarm occured on the PSM Input power is abnormal or PSM unit is broken

Remedy

Check input power to PSM Check the voltage between U-V,V-W,and U-W. Change PSM unit

Field diagnosis

The external fan of the amplifier module is faulty.

What to check

  • Replace the fan; check its connector and its fuse.
  • Note: R-J3iB/R-30iA generation; on R-30iB, look for SRVO-123/SRVO-014.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →