LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SRVO-014 — WARN Fan motor abnormal

Warning
Hardware
cabinet cooling
Controllers
R-J3iB / R-30iA / R-30iB
FANUC class
WARN

FANUC SRVO-014 (“WARN Fan motor abnormal”): A fan motor in the control unit is abnormal. First check: Check the fan motors and fan motor connection cables. Likely part: Cooling fan (Cooling fan).

Updated 2026-10-22 · LogrobotLM reference

Description

A fan motor in the control unit is abnormal.

Remedy

Check the fan motors and fan motor connection cables. Replace any faulty fan motor(s) and/or cable(s).

Field diagnosis

A cabinet fan has stopped; the number in parentheses identifies the fan (1, 2, or both). One minute after the alarm, the robot stops and the teach pendant no longer responds.

What to check

  • Check the fans and their cables, replace the faulty fan; then the backplane unit, then the main board (full backup beforehand).
  • Note: Replace fans in pairs: the second one is the same age.

Part to check / replace

FANUC SRVO-014 points to the hardware below — start here before ordering.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.

Related codes

Same hardware involved

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →