FANUC Alarm SRVO-295 — SERVO SVM COM alarm(G:%d A:%d)
FANUC SRVO-295 (“SERVO SVM COM alarm(G:%d A:%d)”): Discharge power of PSM dischege is abnormal Motion is too agressive. First check: Change program speed to be lower Or check whether Fan for PSMR is working If the fan is out of order, exchange the fan
Updated 2026-08-29 · LogrobotLM reference
Description
Discharge power of PSM dischege is abnormal Motion is too agressive. Fan, which is
Remedy · Remède
Change program speed to be lower Or check whether Fan for PSMR is working If the fan is out of order, exchange the fan
Frequently asked · Questions fréquentes
- What does FANUC alarm SRVO-295 mean?
- FANUC SRVO-295 (“SERVO SVM COM alarm(G:%d A:%d)”): Discharge power of PSM dischege is abnormal Motion is too agressive. Fan, which is
- How do you troubleshoot FANUC alarm SRVO-295?
- Change program speed to be lower Or check whether Fan for PSMR is working If the fan is out of order, exchange the fan
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →