LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

FANUC Alarm SVGN-136Thickness check cal err: bad deflection

Description

A thickness check calibration point has a deflection value that is not greater than 0.0, or is not in ascending order.

Remedy · Remède

Go to the Gun Setup Utility Screen (UTILITIES-GUN SETUP) and re-execute Thickness Check Calibration. If the error still occurs, re-master and re-execute Thickness Check Calibration.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.