FANUC Alarm SVGN-138 — Invalid tipwear ratio.
FANUC SVGN-138 (“Invalid tipwear ratio.”): The tip wear ratio for one step wear measurement is invalid (less than 0.0 or greater than 1.0). First check: Set the wear ratio in the Tip Wear measurement macro program to a value between 0 and 1.
Updated 2026-09-17 · LogrobotLM reference
Description
The tip wear ratio for one step wear measurement is invalid (less than 0.0 or greater than 1.0).
Remedy
Set the wear ratio in the Tip Wear measurement macro program to a value between 0 and 1. The macro program WR_UPDAT is used to perform the Tip Wear measurement with the 1-Step Method. Set the wear-ratio which is found as a parameter in a CALL instruction to the program TWKCALC2, or a similar name. Follow the program comments to find the proper parameter to adjust: CALL TWKCALC2(wear-ratio,AR[2]).
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →