LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free → · Le diagnostic IA qui lit la sauvegarde de votre robot, sans rien téléverser.

FANUC Alarm SVGN-177Thk%smm,CloseLim%smm,StdLim%smm

Description

This is information at pressure shortage.

Remedy · Remède

Incorrect thickness or/and gun close limit would cause a pressure shortage If thikness or/and gun close limit is incorrect, gun tip can not go correct push depth for setpoint pressure The Thk is value which is specifiied in pressure schedule. Check if thikness value in pressure schedule is correct for actual thickness. This CloseLim is present gun close limit,and the StdLim is gun close limit of no-wear down. If CloseLim is too shorter than StdLim, replace gun tip then perform wear down update program. If StdLim is already too short, set the correct standard limit in servo gun setup screen.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.