KUKA Error 1484 — ADHESIVE PRESSURE ERROR

Error

Displayed as KSS01484 on KRC4 / KRC5 controllers

KUKA 1484 (“ADHESIVE PRESSURE ERROR”): The initial pressure of the adhesive is continuously monitored by the PLC during dosing. First check: Check the adhesive equipment, flush if necessary.

Updated 2026-09-09 · LogrobotLM reference

Cause

The initial pressure of the adhesive is continuously monitored by the PLC during dosing. The pressure value was outside the permissible tolerance range. There may be air bubbles in the adhesive supply, or the outlet nozzle is blocked. The check is performed from a PLC user program (bonding technology).

Effect

Stop via braking ramp. All active commands are inhibited.

Troubleshooting

Check the adhesive equipment, flush if necessary.

Related codes