KUKA Error 1499 — ANALOG OUTPUT ALREADY IN USE

Error

Displayed as KSS01499 on KRC4 / KRC5 controllers

KUKA 1499 (“ANALOG OUTPUT ALREADY IN USE”): In the program, an analog output is assigned a second time for cyclical analog output, for example: -- SIGNAL SIG1 $ANOUT[1] -- SIGNAL SIG2 $ANOUT[1] -- ANOUT ON SIG1 = .... First check: Switch off the cyclical analog output: ANOUT OFF SIGNALNAME.

Updated 2026-09-09 · LogrobotLM reference

Cause

In the program, an analog output is assigned a second time for cyclical analog output, for example: -- SIGNAL SIG1 $ANOUT[1] -- SIGNAL SIG2 $ANOUT[1] -- ANOUT ON SIG1 = .... -- ANOUT ON SIG2 = ....

Effect

Stop via braking ramp. All active commands are inhibited.

Troubleshooting

Switch off the cyclical analog output: ANOUT OFF SIGNALNAME.