KUKA Error 1540 — INTERRUPT STRUCTURE OVERFLOW
ErrorDisplayed as KSS01540 on KRC4 / KRC5 controllers
KUKA 1540 (“INTERRUPT STRUCTURE OVERFLOW”): At controller level and robot level, more than 16 "slow" variables in total have been used in the logical expressions of the INTERRUPT DECL commands. First check: Use fewer predefined variables.
Updated 2026-09-09 · LogrobotLM reference
Cause
At controller level and robot level, more than 16 "slow" variables in total have been used in the logical expressions of the INTERRUPT DECL commands.
Effect
Stop via braking ramp. All active commands are inhibited.
Troubleshooting
Use fewer predefined variables. If necessary, combine expressions with CYCFLAGS.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →