KUKA Error 2335 — COMBINED SIGNALS GREATER THAN 32 BITS

Displayed as KSS02335 on KRC4 / KRC5 controllers

KUKA 2335 (“COMBINED SIGNALS GREATER THAN 32 BITS”): A maximum of 32 inputs or outputs can be grouped into one signal. First check: Modify the program.

Updated 2026-09-09 · LogrobotLM reference

Cause

A maximum of 32 inputs or outputs can be grouped into one signal. Example: SIGNAL $DIGIN1 $IN[200] TO $IN[232] (corresponds to 33 inputs)

Effect

The program cannot be executed.

Troubleshooting

Modify the program. Example: SIGNAL $DIGIN1 $IN[200] TO $IN[231]