ABB Error 20032 — Revolution counter not updated
WarningABB 20032 (“Revolution counter not updated”): The revolution counter of one or more axes is invalid — after battery discharge, SMB replacement or measurement cable disconnection. Likely part: Compteurs de tours / Batterie SMB (revolution counter / battery SMB).
Updated 2026-09-17 · LogrobotLM reference
What it means
The revolution counter of one or more axes is invalid — after battery discharge, SMB replacement or measurement cable disconnection. Fine positioning is lost until counters are updated.
What to check
- Update revolution counters at the calibration marks (per axis).
- If it recurs: measure the SMB backup battery and inspect the measurement cabling.
- Recurring together with SMB communication faults → the measurement link is the suspect.
Part to check / replace
ABB 20032 points to the hardware below — start here before ordering.