ABB Error 38101 — SMB communication failure
ErrorABB 38101 (“SMB communication failure”): The serial link between the controller and the Serial Measurement Board (SMB) failed. Likely part: Liaison SMB d'axes (link SMB axis).
Updated 2026-09-17 · LogrobotLM reference
What it means
The serial link between the controller and the Serial Measurement Board (SMB) failed. The controller loses axis position feedback — motion stops. Other interventions show it intermittently on one axis first (worn measurement cable), often with 37108, sometimes followed by revolution-counter losses (20032).
What to check
- Inspect the measurement cable end-to-end — especially flexing segments near the faulted axis.
- Reseat/inspect SMB connectors (oxidation, bent pins, tightness).
- Check the SMB battery state; a dying battery adds counter losses (20032).
- If the fault follows one axis under motion, swap-test the cable segment before the SMB itself.
Part to check / replace
ABB 38101 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →