ABB Error 20476 — Safety Controller (SC) … is disabled
ErrorABB 20476 (“Safety Controller (SC) … is disabled”): Safety Controller (SC) arg is disabled: the safety controller is disabled. Likely part: Safety Controller / Configuration de sécurité (Safety Controller / Configuration de sécurité).
Updated 2026-10-22 · LogrobotLM reference
What it means
Safety Controller (SC) arg is disabled: the safety controller is disabled. Consequence: all safety supervision is inactive — a real safety risk, this is not a simple information message.
What to check
- Do not operate the cell in this state.
- Load a safety configuration into the Safety Controller from the SafeMove configurator in RobotStudio.
- Check: safety configuration PIN missing or incorrect, configuration empty, corrupted or missing, Safety Controller connected to the wrong SMB bus, I/O power supply missing.
- A B-Start restores the entire system configuration, safety parameters included.
- Note: Very frequent message at the end of the Elog after a board replacement or an incomplete restore. The robot can run while the supervision is dead.
Part to check / replace
ABB 20476 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →