ABB Error 34268 — Rectifier / DC-link fault
Error / Erreur🇫🇷 Redresseur / DC-Link
ENTRAÎNEMENT : REDRESSEUR, DC-LINK, BLEEDER, ENERGY BANK (34xxx, 36xxx, 386xx S4C+)
ABB 34268 (“Rectifier / DC-link fault”): Rectifier / DC-link fault — ABB robot hardware event on the rectifier / DC-link (IRC5). Likely part: Redresseur / DC-Link (rectifier / DC-link).
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
Rectifier / DC-link fault — ABB robot hardware event on the rectifier / DC-link (IRC5). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
Erreur de charge du bus DC-Link.
What to check · Que vérifier
- Inspect the rectifier / DC-link, its wiring and connections first.
- Match this code against your robot's event-log timeline before swapping parts.
- Follow the French field checks below — they are the tested sequence for this fault.
- Contrôler tension secteur, câblage triphasé, redresseur et circuit de charge; rechercher les défauts d’alimentation associés dans l’Event Log.
- À savoir : Défaut de puissance pouvant être lié au redresseur ou à l’alimentation secteur.
Part to check / replace · Pièce à contrôler / remplacer
ABB 34268 points to the hardware below — start here before ordering. · 34268 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does ABB error 34268 mean?
- ABB 34268 (“Rectifier / DC-link fault”): Rectifier / DC-link fault — ABB robot hardware event on the rectifier / DC-link (IRC5). Seen across controller generations. Severity: Critical. Field diagnosis below (French); your robot's own manual remains authoritative.
- How do you troubleshoot ABB error 34268?
- Inspect the rectifier / DC-link, its wiring and connections first. Match this code against your robot's event-log timeline before swapping parts. Follow the French field checks below — they are the tested sequence for this fault.
- Which part is involved in ABB 34268?
- 34268 points to Redresseur / DC-Link (rectifier / DC-link). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Same hardware involved / Même matériel en cause
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →