ABB Error 37108 — Communication lost with unit
Error / Erreur🇫🇷 Communication perdue avec une unité
3xxxx — Hardware / Matériel
ABB 37108 (“Communication lost with unit”): The controller lost contact with an internal unit. Likely part: DSQC 662 (System power / distribution board) +1 more.
Updated 2026-08-29 · LogrobotLM reference
What it means · Ce que ça veut dire
The controller lost contact with an internal unit. In the field this is regularly seen TOGETHER with 38101 (SMB link) — one physical link failure, two symptoms.
Le contrôleur a perdu le contact avec une unité interne. Sur le terrain, ce code s'observe régulièrement AVEC 38101 (liaison SMB) — une seule liaison physique en défaut, deux symptômes.
What to check · Que vérifier
- Note which unit is cited, then inspect its cable path and connectors.
- If paired with 38101: focus on the serial measurement link (SMB side).
- Flexing cable segments on moving axes are the usual wear point.
- Noter l'unité citée, puis inspecter son cheminement de câble et ses connecteurs.
- Si couplé à 38101 : concentrer sur la liaison série de mesure (côté SMB).
- Les tronçons de câble en flexion sur axes mobiles sont le point d'usure habituel.
Part to check / replace · Pièce à contrôler / remplacer
ABB 37108 points to the hardware below — start here before ordering. · 37108 met en cause l'organe ci-dessous : commencez par là.
- DSQC 662System power / distribution board· Alimentation / distribution systeme
- DSQC 639Alimentation module de commande (DSQC 662) / Câble USB· Alimentation module de commande (DSQC 662) / Câble USB
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does ABB error 37108 mean?
- ABB 37108 (“Communication lost with unit”): The controller lost contact with an internal unit. In the field this is regularly seen TOGETHER with 38101 (SMB link) — one physical link failure, two symptoms.
- How do you troubleshoot ABB error 37108?
- Note which unit is cited, then inspect its cable path and connectors. If paired with 38101: focus on the serial measurement link (SMB side). Flexing cable segments on moving axes are the usual wear point.
- Which part is involved in ABB 37108?
- 37108 points to DSQC 662 (System power / distribution board), DSQC 639 (Alimentation module de commande (DSQC 662) / Câble USB). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →