ABB Error 38103 — SMB / cable SMB / Axis Computer fault
ErrorABB 38103 (“SMB / cable SMB / Axis Computer fault”): Loss of communication between the Axis Computer and the Serial Measurement Board. Likely part: SMB / Câble SMB / Axis Computer (SMB / cable SMB / Axis Computer).
Updated 2026-10-22 · LogrobotLM reference
What it means
Loss of communication between the Axis Computer and the Serial Measurement Board.
What to check
- Check the SMB cable and connectors, shielding/ground, oxidation, power supply and SMB; check for electromagnetic interference.
- Replace the SMB or the cable if necessary.
- Note: Very well documented on IRB 6700/IRC5; other interventions show intermittent faults related to connections, cables or the SMB.
Part to check / replace
ABB 38103 points to the hardware below — start here before ordering.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →