FANUC Alarm APSH-125 — WARN Forcing Process Enabled
FANUC APSH-125 (“WARN Forcing Process Enabled”): It was detected that the Process was DISABLED at the start of this production program. First check: - Don't choose to FORCE the process enable.
Updated 2026-09-17 · LogrobotLM reference
Description
It was detected that the Process was DISABLED at the start of this production program. A choice (or setup selection) has indicated that the Process should be FORCED to the enabled state.
Remedy
- Don't choose to FORCE the process enable. - Change Prog Select-Production Check Process ready setup to NOT Force Condition. - Ensure that Process Enabled input is on at the start of the next production cycle.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →