FANUC Alarm INTP-430 — Dry Run needs other groups

Manufacturer wording — (%s^4, %d^5) Dry Run needs other groups
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC INTP-430 (“Dry Run needs other groups”): The program does not have all motion groups. First check: Enable all motion groups for the program.

Updated 2026-09-17 · LogrobotLM reference

Description

The program does not have all motion groups. All motion groups are required for Dry Run.

Remedy

Enable all motion groups for the program. If some groups should not be affected by Dry Run, set $DRYRUN.$GRP_MASK to indicate which motion groups should be affected. 1 = affect this group; 0 = do not affect this group.