FANUC Alarm PAIN-231 — WARN Enabling ResEnb+MixSol not allowed
FANUC PAIN-231 (“WARN Enabling ResEnb+MixSol not allowed”): An attempt was made to enable the Mix Resin Valve with the Mix Solvent Valve enabled. First check: Check the cycle data table and make sure the Mix Resin and Mix Solvent outputs are never ON at the same time.
Updated 2026-09-17 · LogrobotLM reference
Description
An attempt was made to enable the Mix Resin Valve with the Mix Solvent Valve enabled.
Remedy
Check the cycle data table and make sure the Mix Resin and Mix Solvent outputs are never ON at the same time.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →