FANUC Alarm PAIN-232 — WARN Enabling HrdEnb+MixSol not allowed

FANUC PAIN-232 (“WARN Enabling HrdEnb+MixSol not allowed”): An attempt was made to enable the Mix Hardener Valve with the Mix Solvent Valve enabled. First check: Check the cycle data table and make sure the Mix Hardener and Mix Solvent outputs are never ON at the same time.

Updated 2026-09-17 · LogrobotLM reference

Description

An attempt was made to enable the Mix Hardener Valve with the Mix Solvent Valve enabled.

Remedy

Check the cycle data table and make sure the Mix Hardener and Mix Solvent outputs are never ON at the same time.