FANUC Alarm PAIN-280 — WARN %sZero fluid flow rate detected
Description
All of the conditions were set for fluid to be flowing and a zero flow rate was measured. This may be due to no fluid pressure or pilot air pressure. With a very low flow rate the gain may be too high. One of the following items may be broken: Color Valve, Color select board, gun trigger, flow meter, flow meter pickup, Accuflow interface board, or the 32 point input module. Note, Accuflow automatically changes to Open Loop when this failure occurs.
Remedy · Remède
If fluid can be seen coming from the applicator, check: flow meter, flow meter pickup, Accuflow interface and the 32 point input module. Other- wise check the other items listed above. If it occurs with very low flow rates decrease the Gain modifier.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.