FANUC Alarm PAIN-524 — WARN %sMax. flow is below midpt. output
FANUC PAIN-524 (“WARN %sMax. flow is below midpt. output”): During calibration it was found that the maximum amount of flow occurred with the command output at only the middle (midpoint) of the range. First check: Check that the I/P transducer is the right range, if not replace it.
Updated 2026-08-29 · LogrobotLM reference
Description
During calibration it was found that the maximum amount of flow occurred with the command output at only the middle (midpoint) of the range. This indicates that there is wrong equipment installed or the equipment is faulty . This may also indicate a large air leak.
Remedy · Remède
Check that the I/P transducer is the right range, if not replace it. Check that the booster has the correct ratio, typcially 1 to 1. If the alarm log also has a leak alarm follow the remedies for that alarm If this equipment must be used reduce the Max. control value for this parameter by about 20%.
Frequently asked · Questions fréquentes
- What does FANUC alarm PAIN-524 mean?
- FANUC PAIN-524 (“WARN %sMax. flow is below midpt. output”): During calibration it was found that the maximum amount of flow occurred with the command output at only the middle (midpoint) of the range. This indicates that there is wrong equipment installed or the equipment is faulty . This may also indicate a large…
- How do you troubleshoot FANUC alarm PAIN-524?
- Check that the I/P transducer is the right range, if not replace it. Check that the booster has the correct ratio, typcially 1 to 1. If the alarm log also has a leak alarm follow the remedies for that alarm If this equipment must be used reduce the Max. control value for this parameter by about 20%.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →