FANUC Alarm PALL-149 — Unit Posn out of range
FANUC PALL-149 (“Unit Posn out of range”): The placement position the robot is trying to go to is not reachable. First check: Verify that the value of $UTOOL and/or $MNUTOOL are correct.
Updated 2026-08-29 · LogrobotLM reference
Description
The placement position the robot is trying to go to is not reachable.
Remedy · Remède
Verify that the value of $UTOOL and/or $MNUTOOL are correct. If the robot stopped while heading towards the pallet, then check the value of Pallet approach length and width in Optimal path setup You may have specified large pallet offsets or you mamight need to specify a correct pallet offset in the Optimal path setup menu.
Frequently asked · Questions fréquentes
- What does FANUC alarm PALL-149 mean?
- FANUC PALL-149 (“Unit Posn out of range”): The placement position the robot is trying to go to is not reachable.
- How do you troubleshoot FANUC alarm PALL-149?
- Verify that the value of $UTOOL and/or $MNUTOOL are correct. If the robot stopped while heading towards the pallet, then check the value of Pallet approach length and width in Optimal path setup You may have specified large pallet offsets or you mamight need to specify a correct pallet offset in the Optimal path…
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →