FANUC Alarm PNT1-583 — Cal. table adapted out tolerance
Manufacturer wording — %sCal. table adapted out tolerance
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC PNT1-583 (“Cal. table adapted out tolerance”): The fluid pressure or fluid viscosity for the current color has changed dramatically. First check: Correct the fluid pressure or viscosity for the current color.
Updated 2026-09-17 · LogrobotLM reference
Description
The fluid pressure or fluid viscosity for the current color has changed dramatically. This change has occurred since the last calibration of this color. The change was beyond the percentage value setting of the Adaptive tolerance parameter.
Remedy
Correct the fluid pressure or viscosity for the current color. If the pressure or viscosity was purposely changed, then the color can be calibrated to eliminate this alarm. The setting for the Adaptive tolerance can be increased if the variation shown by the calibration table for this color is acceptable.