FANUC Alarm PNT1-704 — Zero turbine speed timeout

Manufacturer wording — %sZero turbine speed timeout
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT1-704 (“Zero turbine speed timeout”): All of the conditions were set for the turbine to be spinning but a zero speed was measured for a set time period. First check: If the turbine can be seen spinning, check the following: the speed sensor interface and speed sensor pickup.

Updated 2026-09-17 · LogrobotLM reference

Description

All of the conditions were set for the turbine to be spinning but a zero speed was measured for a set time period. This might be due to no turbine air pressure or pilot air pressure. One of the following items might be broken: the I/P transducer, speed sensor pickup, speed sensor interface. The Zero speed timeout might be set too short.

Remedy

If the turbine can be seen spinning, check the following: the speed sensor interface and speed sensor pickup. Otherwise, check the other items listed above. Possibly increase the Zero speed timeout by about 50%.