FANUC Alarm PNT2-171 — Auto Calibration aborted
Description
The Accustat auto calibration could not continue. This is normally the result of an operation time out. The auto calibration can abort for several reasons. The function of this alarm is as follows. First, the Auto Calibration Aborted alarm will post if an error has occurred. The next alarm will contain the cause of the auto calibration to abort. Cause 1: While searching for the minimum or maximum flow rates in the cal table, the calibration timed-out by reaching the maximum number of attempts to establish the minimum or maximum flow rate output values. This can be a result of improper fluid restriction selection, non-attainable cal table flow ranges, or a bad fluid regulator. The resulting alarms would be PNT1-251, Failed to find upper limit or PNT1-252, Failed to find lower limit. Cause 2: Calibration resulted in non-increasing command values in the calibration table data. The slope of the calibration table is negative. Increasing output values do not result in increased flow rate. The result error code will be PNT1-254 Non-increasing cal table. Cause 3: The calibration routine calculated output values that are above or below the maximum or minimum output values defined in the Applicator Parameters for the fluid regulator. The minimum output values in counts are (low- res: 200, hi-res: 1600) and the maximum output values in counts are (low-res: 1000, and hi-res: 8000). The restrictor size is not compatible with the desired flow rate range and the material attempting to be calibrated. The resulting error codes will be PNT1-255 Calculated output > max output or PNT1-256 Calculated output < min output. Cause 4: The calibration has been aborted by the user or has been interrupted by another fault. If the cell has been emergency stopped during the calibration. The robot failed to reach the proper location in order to calibrate. See other alarms to determine the cause of the fault.
Remedy · Remède
Remedy 1: Increase the number of Maximum Calibration Trys in the AccuStat setup. Verify restrictor, regulator and calibration flow rate range in the AccuStat Color Data for that valve. Remedy 2: Verify all equipment is operating properly. Check the linear potentiometer feedback (AIN[1, DISP], the regulator operation, and that trigger is opening and closing properly. Verify attainable values have been set in the AccuStat Color Data for the requested minimum and maximum flow rates. Remedy 3: Verify that the fluid regulator is functioning properly. Change the fluid restrictor size to better accommodate the requested flow rate range. Change the requested flow rate range in the AccuStat Color Data setup. Remedy 4: Determine the cause of the fault to the robot. Check the alarm log to aid finding the cause of the fault. If the robot has not moved to position, verify that the proper path has been taught.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.