FANUC Alarm PNT2-172 — Failed to find Upper limit
Description
Accustat could not reach the upper flow limit in the number of times set at the calibration screen. The upper limit flow rate can not be achieved. Fluid restricter is too small. The flow rate or can position feedback is unstable.
Remedy · Remède
Verify all equipment is working properly. Check Color Data upper limit. Check applicator parameters to make sure that App Parameter Max limit is not below the AccuStat Color Data upper limit. Increase Auto cal hi/low tolerance or Trys for hi/low from the AccuStat setup screen. Check feedback.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.