FANUC Alarm PNT2-575 — %s0 fluid flow rate timeout
FANUC PNT2-575 (“%s0 fluid flow rate timeout”): All of the conditions were set for fluid to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. First check: Check that the gun is properly triggering. Likely part: Fluid flow meter (Fluid flow meter).
Updated 2026-08-29 · LogrobotLM reference
Description
All of the conditions were set for fluid to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. This may be caused by: a broken applicator trigger, a loss of fluid supply pressure, a broken fluid flow meter, a broken cable (to the flow meter), or a Zero flow timeout value that is too short. Note, AccuFlow temporarily automatically changes to Open Loop when this alarm occurs.
Remedy · Remède
Check that the gun is properly triggering. If fluid was observed to be flowing, check and possibly replace the fluid flow meter. Possibly increase the Zero flow timeout parameter (by about 25%).
Part to check / replace · Pièce à contrôler / remplacer
FANUC PNT2-575 points to the hardware below — start here before ordering. · PNT2-575 met en cause l'organe ci-dessous : commencez par là.
Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.
Frequently asked · Questions fréquentes
- What does FANUC alarm PNT2-575 mean?
- FANUC PNT2-575 (“%s0 fluid flow rate timeout”): All of the conditions were set for fluid to be flowing and a zero flow rate was measured for longer than the Zero flow timeout parameter. This may be caused by: a broken applicator trigger, a loss of fluid supply pressure, a broken fluid flow meter, a broken cable (to…
- How do you troubleshoot FANUC alarm PNT2-575?
- Check that the gun is properly triggering. If fluid was observed to be flowing, check and possibly replace the fluid flow meter. Possibly increase the Zero flow timeout parameter (by about 25%).
- Which part is involved in FANUC PNT2-575?
- PNT2-575 points to Fluid flow meter (Fluid flow meter). Confirm the real cause against the robot backup before replacing a part.
Related codes / Codes liés
Same hardware involved / Même matériel en cause
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →