FANUC Alarm PNT2-664 — %sWarning, learn item failed
FANUC PNT2-664 (“%sWarning, learn item failed”): While completing operations to measure the equipment delays, the equipment did not respond within the expected timeout. First check: Retry the operation by setting the Equipment learn to Redo and calibrate again.
Updated 2026-08-29 · LogrobotLM reference
Description
While completing operations to measure the equipment delays, the equipment did not respond within the expected timeout.
Remedy · Remède
Retry the operation by setting the Equipment learn to Redo and calibrate again. Check for other AccuAir alarms in the alarm log then follow the remedies for those alarms. If there are no other alarms follow the remedies for the Failed to reach setpoint alarm.
Frequently asked · Questions fréquentes
- What does FANUC alarm PNT2-664 mean?
- FANUC PNT2-664 (“%sWarning, learn item failed”): While completing operations to measure the equipment delays, the equipment did not respond within the expected timeout.
- How do you troubleshoot FANUC alarm PNT2-664?
- Retry the operation by setting the Equipment learn to Redo and calibrate again. Check for other AccuAir alarms in the alarm log then follow the remedies for those alarms. If there are no other alarms follow the remedies for the Failed to reach setpoint alarm.
Related codes / Codes liés
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →