FANUC Alarm PNT2-666%sCal. table adapted out, down

Description

The relationship of the output command to the flow rate obtained has changed significantly since the last calibration. There is now a smaller output required to get the same flow rate. This can be caused by: air leaks, a loose air cap or a significant increase of air supply pressure Note that the system continues to close the loop and generally maintain requested flow rates even after this alarm if there are no other alarms occurring. This alarm can provide early warning of the possible failures. This alarm is controlled by the Adaptive tolerance parameter.

Remedy · Remède

Check that the air cap is tight on the gun. Check, clean and possibly replace the air cap. Check for leaks in air lines or at fittings. Check for cracks or breaks in the gun. Check for a large increase of air supply pressure. Recalibrate to immediately clear the alarm. Increase the Adaptive tolerance parameter to allow larger changes without alarming

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.