LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm PNT2-912 — Low Trigger Torque

Manufacturer wording — %sLow Trigger Torque
The manual prints placeholders; your controller fills them in with the real group, axis or number.

FANUC PNT2-912 (“Low Trigger Torque”): The torque threshold on the canister motor did not reach the minimum torque threshold value during the fill through trigger step of the fill or refill cycle. First check: Check the paint supply for the current color in the canister or reduce the torque threshold value or the fill through trigger timeout value.

Updated 2026-09-17 · LogrobotLM reference

Description

The torque threshold on the canister motor did not reach the minimum torque threshold value during the fill through trigger step of the fill or refill cycle.

Remedy

Check the paint supply for the current color in the canister or reduce the torque threshold value or the fill through trigger timeout value.

Related codes