FANUC Alarm PNT2-928%sHood/Deck Opener Lost Part

Description

The Hood/Deck opener lost the part while softfloat was enabled, resulting in the hook to rotate to the Part lost position.

Remedy · Remède

Determine if the TP program needs to disable softfloat prior to this location. If programming is correct, to continue, reposition the part on the hook and issue a continue on the opener. A cancel can be initiated to cancel the job, which automatically disables Softfloat.

Related codes / Codes liés

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique.