LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm PRIO-083 — STOP Digital I/O is not recovered

Error
Hardware
I/O Link and process I/O
Controllers
R-J3iB / R-30iA
FANUC class
PAUSE.G

FANUC PRIO-083 (“STOP Digital I/O is not recovered”): Digital output port states are not recovered when semi-hot start is enabled be I/O device configuration or assignments have changed. First check: Cold start the application.

Updated 2026-10-22 · LogrobotLM reference

Description

Digital output port states are not recovered when semi-hot start is enabled be I/O device configuration or assignments have changed. All outputs will be reset to OFF.

Remedy

Cold start the application.

Field diagnosis

At semi-hot start, the output state could not be restored because the I/O configuration or assignment has changed; all outputs are reset to OFF.

What to check

  • Perform a Cold start of the application.
  • Note: After a process board replacement, this code is expected once.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →