FANUC Alarm SEAL-041 — STOP Seal not ready
FANUC SEAL-041 (“STOP Seal not ready”): The system ready signal(DI) turns off when the sealant is dispensed. First check: Check the system ready signal of the sealing equipment or disable the system ready signal.
Updated 2026-09-17 · LogrobotLM reference
Description
The system ready signal(DI) turns off when the sealant is dispensed.
Remedy
Check the system ready signal of the sealing equipment or disable the system ready signal.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →