FANUC Alarm SPOT-004 — PAUSE Water flow OK fault …
Manufacturer wording — PAUSE Water flow OK fault %s
The manual prints placeholders; your controller fills them in with the real group, axis or number.
FANUC SPOT-004 (“PAUSE Water flow OK fault …”): The water flow OK input is low. First check: Check the input from the weld controller, and reset as necessary.
Updated 2026-09-17 · LogrobotLM reference
Description
The water flow OK input is low.
Remedy
Check the input from the weld controller, and reset as necessary.
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →