FANUC Alarm SRVO-015SERVO System over heat

FANUC SRVO-015 (“SERVO System over heat”): The temperature of the control unit is higher than the specified value. First check: 1. If the ambient temperature is higher than the specified temperature (45 degrees C), provide ventilation to reduce the ambient temperature to the specified value. Likely part: Cooling fan (Cooling fan).

Updated 2026-08-29 · LogrobotLM reference

Description

The temperature of the control unit is higher than the specified value.

Remedy · Remède

1. If the ambient temperature is higher than the specified temperature (45 degrees C), provide ventilation to reduce the ambient temperature to the specified value. 2. Check that the fans are operating normally. If not, check the fan motors and fan motor connection cables. Replace any faulty fan motor(s) and/or cables(s). 3. If the thermostat on the backplane printed circuit board is faulty , replace the backplane unit.

Part to check / replace · Pièce à contrôler / remplacer

FANUC SRVO-015 points to the hardware below — start here before ordering. · SRVO-015 met en cause l'organe ci-dessous : commencez par là.

Tap a part for every code that points to it — and verify the exact variant for your controller before ordering. · Touchez une pièce pour tous les codes qui la citent ; vérifiez la variante exacte avant commande.

Frequently asked · Questions fréquentes

What does FANUC alarm SRVO-015 mean?
FANUC SRVO-015 (“SERVO System over heat”): The temperature of the control unit is higher than the specified value.
How do you troubleshoot FANUC alarm SRVO-015?
1. If the ambient temperature is higher than the specified temperature (45 degrees C), provide ventilation to reduce the ambient temperature to the specified value. 2. Check that the fans are operating normally. If not, check the fan motors and fan motor connection cables. Replace any faulty fan motor(s) and/or…
Which part is involved in FANUC SRVO-015?
SRVO-015 points to Cooling fan (Cooling fan). Confirm the real cause against the robot backup before replacing a part.

Related codes / Codes liés

Same hardware involved / Même matériel en cause

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. · Informations indicatives issues du terrain — le manuel du constructeur et ses procédures de sécurité font foi. Ne shuntez jamais un organe de sécurité ; consignez (LOTO) avant toute intervention physique. How this reference is built →