FANUC Alarm SRVO-211 — SERVO TP OFF in T1,T2
FANUC SRVO-211 (“SERVO TP OFF in T1,T2”): Teach Pendant is disabled when mode switch is T1 or T2 and Robot1 and Robot2 are disconnected Or mis-wiring of hardware connection First check: Change the TP Enable/Disable switch to ON And press RESET If the reset is not effective, correct hardware connection
Updated 2026-09-17 · LogrobotLM reference
Description
Teach Pendant is disabled when mode switch is T1 or T2 and Robot1 and Robot2 are disconnected Or mis-wiring of hardware connection
Remedy
Change the TP Enable/Disable switch to ON And press RESET If the reset is not effective, correct hardware connection
Related codes
Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →