LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SRVO-260 — SERVO Chain 1 (NTED) abnormal

FANUC SRVO-260 (“SERVO Chain 1 (NTED) abnormal”): A Single chain 2 (0V) failure occurred when the Non Teacher Enabling Device was released. First check: 1. Repair the chain 2 (0V) circuit on the Non Teacher Enabling Device hardware.

Updated 2026-09-17 · LogrobotLM reference

Description

A Single chain 2 (0V) failure occurred when the Non Teacher Enabling Device was released.

Remedy

1. Repair the chain 2 (0V) circuit on the Non Teacher Enabling Device hardware. 2. Set the CHAIN FAILURE detection item to TRUE on the SYSTEM/CONFIG screen and press the RESET button on the teach pendant.

Related codes