FANUC Alarm SRVO-278 — SYSTEM TP E-stop(SVEMG abnormal)

Error
Hardware
emergency stop and dual safety chains
Controllers
R-J3iB / R-30iA / R-30iB
FANUC class
SYSTEM

FANUC SRVO-278 (“SYSTEM TP E-stop(SVEMG abnormal)”): Status of MON1,MON2,MON3 signals are abnormal on COLD START Value shows MON1,MON2,MON3 signal status Bit 0: MON1 ON,Bit 1: MON2 ON,Bit 3: MON3 ON First check: Repair the circuit of MON1,MON2,MON3 on E.STOP unit

Updated 2026-10-22 · LogrobotLM reference

Description

Status of MON1,MON2,MON3 signals are abnormal on COLD START Value shows MON1,MON2,MON3 signal status Bit 0: MON1 ON,Bit 1: MON2 ON,Bit 3: MON3 ON

Remedy

Repair the circuit of MON1,MON2,MON3 on E.STOP unit

Field diagnosis

The teach pendant button was pressed without the emergency stop line being cut; latched version of SRVO-202.

What to check

  • Release, then switch the mains power off and back on.
  • If it repeats: teach pendant, teach pendant cable, then main board and emergency stop board (backup before replacement).
  • Note: The teach pendant is the cause in the vast majority of cases.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →