LogrobotLM — AI fault diagnosis for ABB · KUKA · FANUC robots. It reads your robot backup in your browser (never uploaded) and pinpoints the fault. Try it free →

FANUC Alarm SRVO-277 — SYSTEM Panel E-stop(SVEMG abnormal)

Error
Hardware
emergency stop and dual safety chains
Controllers
R-J3iB / R-30iA / R-30iB
FANUC class
SYSTEM

FANUC SRVO-277 (“SYSTEM Panel E-stop(SVEMG abnormal)”): The teach pendant emergency stop push button is pressed and miswiring on SVEMG is detected. First check: Check the wiring of SVEMG.

Updated 2026-10-22 · LogrobotLM reference

Description

The teach pendant emergency stop push button is pressed and miswiring on SVEMG is detected.

Remedy

Check the wiring of SVEMG. If the wiring of SVEMG is not connected, correct the wiring of SVEMG. If the wiring has no problem, twist the teach pendant emergency stop push button clockwise to release. Press RESET. Refer to the maintenance manual for details.

Field diagnosis

The operator panel button was pressed without the emergency stop line being cut; latched version of SRVO-201.

What to check

  • Release the button, switch the mains power off and back on.
  • If the code reappears at the next press: main board, then emergency stop board, then servo amplifier (full backup beforehand).
  • A very slow press can trigger the code without any failure.
  • Note: Never clears with RESET alone.

Related codes

Indicative field information — the robot manufacturer's manual and safety procedures always prevail. Never bypass a safety device; apply lockout/tagout (LOTO) before any physical intervention. How this reference is built →