FANUC Alarm SVGN-113 — Gun must be open.

FANUC SVGN-113 (“Gun must be open.”): The tip wear setup or update program started with the gun closed. First check: Open the tips, then execute the tip wear measurement program again.

Updated 2026-09-17 · LogrobotLM reference

Description

The tip wear setup or update program started with the gun closed.

Remedy

Open the tips, then execute the tip wear measurement program again. If the problem persists, master the gun, then execute the tip wear measurement program again.